[Cmf5] Line/Trunk Memory/Alarm Memory Read - NEC Univerge NEAX 2000 IPS Command Manual

Internet protocol server
Hide thumbs Also See for Univerge NEAX 2000 IPS:
Table of Contents

Advertisement

COMMAND CODE TITLE:
F5
FUNCTION:
This command is used only for maintenance.
DO NOT USE this command without the assistance of a NEC engineer.
ASSIGNMENT PROCEDURE:
ST +
F5Y
+ DE
DATA TABLE:
Y
fX
fXXXXXXXX
fFX
fFXXXXXXXX
fD000
0
fD255
fEEX
fEEXXXXXXXX
,
fEFX +
fEFXXXXXXXX +
XYY
1
LINE/TRUNK MEMORY/ALARM MEMORY READ
+
1ST DATA
+
DE
1ST DATA
f=Status Memory Block number
(0-3)
Single Line station/Virtual Line
station number (1-8 digits)
X=0-9, A (*), B (#)
f=Status Memory Block number
(0-3)
term
D
number <X-XXXXXXXX>
represents My Line number
f=Status Memory Block number
(0-3)
Trunk number
f=Status Memory Block number
(0-3)
PS Line station number
<X-XXXXXXXX>
+ B
f=Status Memory Block number
(0-3)
,
+ B
ISDN Line station number
<X-XXXXXXXX>
B=B channel number (0/1)
LEN
X=PIM number (0-7)
YY= Port number (00-63)
READOUT DATA
(STATUS INFORMATION)
Basic memory dump data of
station/trunk
Basic memory dump data of
station/trunk
– 769 –
CMF5
REMARKS
Continued on next page
NWA-008844-001 Rev.5.0
91ch3008.fm

Advertisement

Table of Contents
loading