Technical Specifications
Item
Thermal transition
Humidity (RH), ambient
(noncondensing)
Altitude (operating and
nonoperating)
Sound power level
(LwAD)
Airflow
Shock
Sine Vibration
Random Vibration
(Operating)
Random Vibration
(Nonoperating and
Storage)
5
Minimum ambient temperature for cold startup is 0ºC
6
Short-term exceptional conditions are for no longer than a one-year period of—96 consecutive hours,
or 360 hours total, or 15 occurrences.
Cisco Catalyst 9600 Series Switches Hardware Installation Guide
92
Specification
Hot to cold—at a maximum rate of 86°F (30°C) per hour
Cold to hot—at maximum rate of 204.8°F (96°C) per hour
Operating, nonoperating and storage —10 to 95 percent
-60 to 3000m (-197 to 9843 feet)
LwAD—74.7 dBA
This is with four power supply modules installed and delivering 50 percent of
rated output power; measured according to International Organization for
Standardization (ISO) 7779 and declared according to ISO 9296.
Chassis—Right to left (when facing the front of the chassis)
Power supply—Front to back (forward air flow)
Operating—5G 11ms (Half-sine)
Nonoperating and storage— 15G 11ms (Half-sine)
• Operating— 0.15G (10Hz-500Hz)
• Nonoperating and storage— 0.8G (10Hz-500Hz)
Acceleration Spectral
Spectral Break Point
Frequencies
Density
2.5 – 5 Hz
-
5 – 100 Hz
0.1 [(m/s²)²]/Hz
(0.001 g²/Hz)
100 – 200 Hz
-
Spectral Break Point
Acceleration Spectral
Frequencies
Density
2.5 – 5 Hz
-
5 – 100 Hz
1.0 [(m/s²)²]/Hz*
(0.01 g²/Hz)
100 – 200 Hz
-
Technical Specifications
Slope
6 db /octave
-
-24 db /octave
Slope
6 db /octave
-
-24 db /octave