Service and Maintenance
For public disclosure
6.
Install the replacement battery (IC690ACC001) in the retaining clip with the positive
(+) side up. That is, with the + side away from the circuit board. The coin cell must
be inserted at an angle to go under the positive terminal clip and then slid into the
carrier and snapped into place.
7.
Replace and secure the interior lid using four Phillips-head screws.
8.
Reconnect the internal power cable.
Reattach the two RTM sections together without pinching the internal power cable,
9.
and tighten the four captive screws to secure them.
10. Carefully align the RTM to the display panel and push until the connector is seated.
11. Tighten the six captive screws to fasten the RTM.