Function overview

The underfloor heating controller
offers the following functions:
5 controllable temperature zones, extendable to 8
Up to 3 thermal actuators can be connected per zone
Normally open or normally closed
thermal actuators can be used
Integrated pump relay
Boiler feedback
– Analog (only HCE80/HCC80)
– Integrated relay with floating contact
42 V AC/VDC (only at HCE80R, HCC80R)
– Wireless via relay BDR91
Underfloor heating controller can be
switched between heating and cooling
1 antenna (internal or external) can
be used for 3 controllers
Rapid installation through screwless
terminals of the thermal actuators
Intelligent controlling via fuzzy logic
Simple diagnoses of the wireless transmission
Operating state display via LEDs
Antenna
Pump relay
Analog output
Boiler feedback radio
Boiler feedback relay
!
The pump relay 230 V AC is not floating.
HCE80(R) / HCC80(R) Mounting and operation
HCE80
External
230 V AC internal
Available
External with BDR91
Not available
HCE80R
External
230 V AC internal
Not available
External with BDR91
42 V AC/VDC
HCC80
Internal
230 V AC internal
Available
External with BDR91
Not available
5
HCC80R
Internal
230 V AC internal
Not available
External with BDR91
42 V AC/VDC