Download Print this page

Troubleshooting - Makita VC3012L Original Operating Instructions

Advertisement

A dust test must be performed at least once every year by Makita service or a trained person. This test
includes, for example, whether there is damage to the filter, the vacuum cleaner is sealed to the air
and the control equipment works properly.
Disposal of filter elements, filter bags and disposal bags
Discard filter elements, filter bags and disposal bags in accordance with the national regulations.
Transport
Before transporting the dirt tank, close all the locks. Do not tilt the cleaner if there is liquid in the dirt
tank. Do not use a crane hook to lift the cleaner.
Storage
CAUTION – The appliance must be stored in a dry place and protected from frost.
Recycling the vacuum cleaner
As specified in European Directive 2012/19/EC on old electrical and electronic appliances,
used electrical goods must be collected separately and recycled ecologically. Contact your local
authorities or your nearest dealer for further information.
Guarantee
Our general conditions of business are applicable with regard to the guarantee. Subject to change as a
result of technical alterations.
Spare parts and accessories
Filter element
Fleece filter bag
Disposal bag
Exploded drawings and parts lists are available on our homepage: www.makita.com

Troubleshooting

‡ Motor does not start
‡ Motor does not run in
automatic mode
‡ Reduced suction power
Downloaded from
www.Manualslib.com
Description
Fault
> Fuse in mains plug has blown.
> Overload protection switch has
> Power tool is defective or not
> Suction power selected with
> Clogged suction hose/nozzle.
> Seal/tank rim between the
> Filter bag is full.
manuals search engine
Cause
tripped.
connected properly.
suction power control is to low.
upper section of the cleaner
and the dirt tank is dirty/
defective.
Makita VC3012L
Order no.
P-70219
P-84078
P-70297
Remedy
Reset the fuse.
Switch off the vacuum cleaner
and allow it to cool for approx. 5
minutes. If it can not be started
again, contact the Makita
service department.
Check that the power tool
works or that the plug is
inserted correctly.
Set suction power in
accordance with section
"Suction power control".
Clean suction hose/nozzle.
Clean/replace seal.
See section "Replacing the
filter bag".
D
GB
F
NL
I
N
S
DK
SF
E
P
GR
TR
SLO
HR
SK
CZ
PL
H
RO
BG
RUS
EST
LV
LT
AL
MK
SR
UK
17