Configuring the Transport Stream Information
Setting up the Auto Synchronization Options
The ASI, MoIP, IP Data 1/Data 2 Auto Sync area or the Auto Map front panel menu allows you to configure
the DPM without editing each output channel and PID separately.
Step 1
Do one of the following:
• Web GUI (single-stream unit): From the D9800 web GUI, choose Transport Stream > ASI Output or MPEG
over IP Output and refer to the Auto Sync area.
• Front Panel (single-stream unit): From the Main Menu of the D9800 front panel, choose Setup > Outputs > TS
Out > ASI or MOIP.
• Web GUI (multi-stream unit): From the D9800 web GUI, choose Transport Stream > ASI 1 Output, ASI 2
Output, IP Data 1/Data 2 Output, or IP Data 3/Data 4 Output and refer to the Auto Sync area.
• Front Panel (multi-stream unit): From the Main Menu of the D9800 front panel, choose Setup > Outputs > TS
Out > ASI1, ASI2, IP1/2, or IP 3/4.
Step 2
From the Enable Auto Fix for Collision drop-down list, or the Auto Map front panel menu, choose Yes for the DPM
to resolve channel and PID collisions automatically on the transport outputs. New values are assigned to the parameters
that caused the conflict. The new assigned values are not used by any incoming transport or other PE outputs. If a collision
is detected, you can review the new changes and click Apply to accept the new changes.
Choose No and a detailed list of all the conflicts is displayed in the Output Channel and PID Conflicts table (click View
Conflicts) when a conflict occurs. You can then resolve the conflicts manually. For information on resolving conflicts,
see
Resolving Conflicts, on page
Step 3
From the Enable Auto Map For Auxiliary PEs drop-down list, choose Yes for the DPM to set the output actions for
all the Auxiliary PEs to MAP when the Output Mode is set to Transcode. The Enable Auto Fix for Collision is
automatically set to Yes. If the Enable Fixed Table Output is set to Yes, the output configuration for the auxiliary PEs
is determined by the fixed output table options when you resynchronize the output channels and PIDs to match the input
programs. The DPM resolves any output conflicts automatically, even if the Enable Auto Fix for Collision is set to No.
This setting is for multi-stream units only.
Step 4
Apply your changes.
Setting up the Resynchronize All Option
Step 1
Do one of the following:
• Web GUI (single-stream unit): From the D9800 web GUI, choose Transport Stream > ASI Output or MPEG
over IP Output, and refer to the Auto Sync area.
• Web GUI (multi-stream unit): From the D9800 web GUI, choose Transport Stream > ASI 1 Output, ASI 2
Output, IP Data 1/Data 2 Output, or IP Data 3/Data 4 Output, and refer to the Auto Sync area.
13. The Enable Auto Map for Auxiliary PE is automatically set to No.
Cisco D9800 Network Transport Receiver Version 3.01 Installation and Configuration Guide