4-2 Classification of Function

In this system, all functions are classified into four categories for fixing stable
measurement and various outputs.
Classification
Function setting for stable measurement by improving accuracy of laser
Head Setting
emission intensity
Function setting related to output data processing
OUT Setting
Function setting for common setting of "Head setting" and "OUT Setting".
Common Setting
System Setting
System setting such as "Initialization", "Save", and the communication settings.
4-3 Function List & Initial Values
Function
Installation Mode
Measurement Mode
Emission Adjustment
Emission
Area-a
Adjustment
Area
Area-b
Emitted Light
Intensity Search
Alarm Delay Times
Measurement
Surface Reference
Point a
Measuring
Range
Point b
Laser Control
*1 Memory Change : Maximum 16 settings can be saved by performing memory change.
X: Settings can not be changed by performing memory change.
*2 When the initialization is performed with 10mm type (HL-C201A) connected, the default of the installation mode is
specular reflection, the default of the measurement mode is specular reflection [standard].
Details
Selects
the
measurement
diffuse reflection or specular reflection for
the target object.
Selects the most suitable digital operation
type for the target object.
Sets the optimum emitted light intensity
for the measurement area.
This function specifies an emission auto
adjustment area.
Searches the received light intensity of all
measurement surfaces
optimum intensity automatically.
Holds the previous normal value up to the
set
number
of
times
operation.
Selects the counting method of the
surface which is set at "Output Selection".
A given range can be specified for
measurement.
Switches emission/stop of laser.
4-3
Chapter 4 Explanation of Functions
Details
Initial value
type
from
Diffuse*2
Diffuse
[Standard]*2
AUTO
1
512
and sets
the
AUTO
during
alarm
8
Near
3
510
Emission
4
Memory
Ref.
change*1
page
4-7
4-8
4-10
4-11
X
4-13
4-14
4-15
4-16
4-18

Advertisement