5
Value setting command 2
FORMAT
% E E # W
Header
Command
Code: 0 to 5
6
Normal write of buffering data
FORMAT
Header
Command
% E E # W
1
2
.
3
± 0
Subdata: Repeat of "1-character symbol + 3-character integral part

■ Response Communication Data Format

This section explains the 10 format patterns of response communication data
transmitted from HL-C2 to the external host device.
● Read response
1
Read request of setting data
FORMAT
% E E $ R
Header
2
Format 2: Value read 1
FORMAT
% E E $ R
Header
Command
3
Format 3: Value read 2
FORMAT
% E E $ R
Header
Command
Subdata: 1-character symbol + 10-character
Code: 0
Head point::00001 to 99999
4 5 6 7 8 ± 0 1 2
1 2
3 4 5 6 7 8
.
(no zero suppress) + decimal point + 6-character decimal
part"
Command
Subdata: 00000 to 99999
±
0 1 2
Subdata: 1-character symbol + 3-digit integral part
±
0 1 2
Subdata: 1-character symbol + 10-digit numerical
5-9
Chapter 5 External Communication Control
numerical values (no zero suppress)
End point: 00001 to 99999
.
3 4 5 6 7 8
CR
BCC
CR
BCC
.
3 4 5 6 7
(no zero suppress) + decimal point +
6-digit decimal part
3 4 5 6 7 8
values (no zero suppress)
CR
BCC
± 0
5
CR
8
BCC
CR
9
BCC