Chapter 4 Explanation of Functions

■ Trigger Conditions

This function is used for setting the trigger generation conditions when
the buffering mode is set to trigger mode or sample trigger mode.
The trigger conditions are selectable from "At timing input ON", the results
of "judgment output" (HI, LO, HI or LO, HI to GO, LO to GO, HI or LO to
GO), "At an alarm occurred", and "At an alarm released".
The initial value is set to "At timing input ON".
· Note that the settings of "Upper Limit/Lower Limit Value of Judgment Output"
and "Upper Limit/Lower Limit Hysteresis of Judgment Output" become effective
when the result of judgment output is set as a trigger condition.
· Note that the setting of "Number of Alarm Delay Times" becomes effective when
"At an alarm occurred" is set as a trigger condition.
Ex ) When the "Buffering Mode" is set to trigger mode, the operations of each
4
At timing input
ON
At HI
At LO
At HIorLO
When HI turns to GO
When LO turns to GO
When HIorLO turns to GO
At an alarm occurred
At an alarm released
Normally, the measurement value is on hold at timing input ON status;
however, only in the case that the buffering mode is set to trigger mode or
sample trigger mode, and this function is set to "At timing input ON", the
measurement value is not on hold at timing input ON status during buffering
operation.
trigger condition are shown as follows:
Buffering start
Stand-by
Timing output
HIorLO output
GO output
HIorLO output
Meas. status
Meas. status
Trigger generate
(Trigger point)
Accumulation of data
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Alarm
Normal
Alarm
Normal
4-80
Buffering stop or
Accu. amount reached
Meas ope