Honeywell XYR 6000 User Manual page 48

Onewireless wcx series wireless valve position sensor
Hide thumbs Also See for XYR 6000:
Table of Contents

Advertisement

6. 5BMaintenance/Repair
6.1. Replacing Batteries
Step
ATTENTION
Note that both batteries in the WCX Valve Position Sensor are installed with the same
orientation, with each positive terminal facing toward the sensor module.
Install batteries (7) as follows to avoid damage to the batteries and holder:
9
Do not attempt to bend the battery hold down tabs upward. Insert the battery negative end
under the hold-down tab, at an angle, and against the end of the spring. Simultaneously move
the negative end of the battery into position, compressing the spring, and angle the positive end
into the holder. See Figure 10.
Repeat this process for the second battery.
Insert the battery holder into the sensor. Reattach the captive screws (5) and tighten to 0,4 –
10
0,6 N-M (3.5 – 5.3 Lb-in).
Plug cable from potentiometer (4) into Jack J2 on battery board. Note that the potentiometer
11
cable goes to the outside of the antenna cable. See Figure 10.
If the antenna jumper cable was disconnected, use tweezers or needle nose pliers to grip the
12
right angle antenna connector, hold the lower end of the antenna jumper cable steady, and
carefully press the connectors together. A distinct click should be heard as the connector is fully
seated.
NOTE: Honeywell recommends lubricating the cover O-ring (8) and threads with a Silicone
13
Grease such as Dow Corning #55 or equivalent before replacing the cover.
Replace cover, tightening hand tight. If applicable, replace cover lock clamp and two T-15
TORX screws.
Re-install and return sensor to service.
If the unit removal or re-installation caused the input shaft to be rotated enough to make the
14
internal slip clutch slip, then re-setting the device angle must be performed (see section 3).
Dispose of used batteries promptly per local regulations or the battery manufacturer's
15
recommendations. Keep away from children. Do not disassemble and do not dispose of in fire.
38
OneWireless XYR 6000 Wireless Valve Position Sensor User's Manual
Action
Revision 1
1/15/09

Advertisement

Table of Contents
loading

Table of Contents