• Clear, level, stable, dry place for opera-
tor. Do not use the inspection camera
while standing in water.
2. Examine the area or space that you will
be inspecting and determine if the micro
CA-25 Inspection Camera is the correct
piece of equipment for the job.
• Determine the access points to the
space. The minimum opening the cam -
era head can fit through is approximate -
ly
3
/
4
camera head.
• Determine if there are any obstacles
that would require very tight turns in
the cable. The inspection camera ca ble
can go down to a 2" (50 mm) radius
without damage.
• Determine if there is any electrical pow -
er supplied to the area to be inspected.
If so, the power to the area must be
turned off to reduce the risk of electric
shock. Use appropriate lock out proce -
dures to prevent the power from be ing
turned back on during the inspection.
• Determine if any chemicals are pres-
ent, especially in the case of drains. It is
important to understand the specific
safety measures required to work around
any chemicals present. Contact the
chemical manufacturer for required infor-
mation. Chemicals may damage or de-
grade the inspection camera.
• Determine the temperature of the area
and items in the area. The working tem-
perature of the inspection camera is
between 32 and 122 degrees F (0°C -
50°C). Use in areas outside of this
range or contact with hotter or colder
items could cause camera damage.
• Determine if any moving parts are pres-
ent in the area to be inspected. If so,
these parts must be deactivated to pre-
vent movement during inspection to
reduce the risk of entanglement. Use
appropriate lock out procedures to pre-
vent the parts from moving during the
inspection.
If the micro CA-25 Inspection Camera is not
the correct piece of equipment for the job,
other inspection equipment is available from
RIDGID. For a complete listing of RIDGID
products, see the RIDGID catalog, online at
www.RIDGID.com or www.RIDGID.eu.
uality Products Online at:
" (19 mm) in diameter for the 17 mm
GlobalTestSupply
www.
micro CA-25 Inspection Camera
3. Make sure the micro CA-25 Inspec tion
Camera has been properly inspect ed.
4. Install the correct accessories for the ap-
plication.

Operating Instructions

WARNING
Always wear eye protection to protect
your eyes against dirt and other foreign
objects.
Follow operating instructions to reduce
the risk of injury from electrical shock,
entanglement and other causes.
1. Make sure that the inspection camera
and work area have been properly set up
and that the work area is free of by-
standers and other distractions.
LED
Brightness
Decrease
Rotate
Image
Figure 7 – Controls
2. Power On: Press and Hold the power
button for 1 second.
The power status light will come ON. If
the power status light is GREEN, the
micro CA-25 Inspection Camera batteries
are good. If the power status light is RED,
the batteries need to be changed. If the
LED does not turn ON, the batteries need
to be changed.
3. Pre-Form The Cable: If needed for the
area to be inspected, pre-form the cable.
Do not try to form bends with a radius of
less than 2" (50 mm) as this can damage
the cable.
.com
Power
Status
Light
LED Brightness
Increase
Power
7