APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 51 of 51)
ADDR
REGISTER NAME
D3BC
...Repeated for Remote Device 16
D3C0
...Repeated for Remote Device 17
D3C4
...Repeated for Remote Device 18
D3C8
...Repeated for Remote Device 19
D3CC
...Repeated for Remote Device 20
D3D0
...Repeated for Remote Device 21
D3D4
...Repeated for Remote Device 22
D3D8
...Repeated for Remote Device 23
D3DC
...Repeated for Remote Device 24
D3E0
...Repeated for Remote Device 25
D3E4
...Repeated for Remote Device 26
D3E8
...Repeated for Remote Device 27
D3EC
...Repeated for Remote Device 28
D3F0
...Repeated for Remote Device 29
D3F4
...Repeated for Remote Device 30
D3F8
...Repeated for Remote Device 31
D3FC
...Repeated for Remote Device 32
Setting file template values (read only)
ED00
FlexLogic™ displays active
ED01
Reserved (6 items)
ED07
Last settings change date
ED09
Template bitmask (750 items)
F001
UR_UINT16 UNSIGNED 16 BIT INTEGER
F002
UR_SINT16 SIGNED 16 BIT INTEGER
F003
UR_UINT32 UNSIGNED 32 BIT INTEGER (2 registers)
High order word is stored in the first register.
Low order word is stored in the second register.
F004
UR_SINT32 SIGNED 32 BIT INTEGER (2 registers)
High order word is stored in the first register/
Low order word is stored in the second register.
GE Multilin
RANGE
0 to 1
---
0 to 4294967295
0 to 65535
F005
UR_UINT8 UNSIGNED 8 BIT INTEGER
F006
UR_SINT8 SIGNED 8 BIT INTEGER
F011
UR_UINT16 FLEXCURVE DATA (120 points)
A FlexCurve is an array of 120 consecutive data points (x, y) which
are interpolated to generate a smooth curve. The y-axis is the user
defined trip or operation time setting; the x-axis is the pickup ratio
and is pre-defined. Refer to format F119 for a listing of the pickup
ratios; the enumeration value for the pickup ratio indicates the off-
set into the FlexCurve base address where the corresponding time
value is stored.
F012
DISPLAY_SCALE DISPLAY SCALING
(unsigned 16-bit integer)
MSB indicates the SI units as a power of ten. LSB indicates the
number of decimal points to display.
Example: Current values are stored as 32 bit numbers with three
decimal places and base units in Amps. If the retrieved value is
12345.678 A and the display scale equals 0x0302 then the dis-
played value on the unit is 12.35 kA.
D30 Line Distance Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
---
---
---
1
F050
---
1
F001

B.4.2 DATA FORMATS

DEFAULT
B
1 (Enabled)
---
0
0
B-59