B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 12 of 51)
ADDR
REGISTER NAME
Ethernet switch (Read Only Actual Values)
4151
Ethernet switch MAC address
4154
Ethernet switch Port 1 Status
4155
Ethernet switch Port 2 Status
4156
Ethernet switch Port 3 Status
B
4157
Ethernet switch Port 4 Status
4158
Ethernet switch Port 5 Status
4159
Ethernet switch Port 6 Status
415A
Switch Firmware Version
Simple Network Time Protocol (Read/Write Setting)
4168
Simple Network Time Protocol (SNTP) function
4169
Simple Network Time Protocol (SNTP) server IP address
416B
Simple Network Time Protocol (SNTP) UDP port number
Clock (Read/Write Command)
41A0
Real Time Clock Set Time
Clock (Read/Write Setting)
41A2
SR Date Format
41A4
SR Time Format
41A6
IRIG-B Signal Type
41A7
Clock Events Enable / Disable
41A8
Time Zone Offset from UTC
41A9
Daylight Savings Time (DST) Function
41AA
Daylight Savings Time (DST) Start Month
41AB
Daylight Savings Time (DST) Start Day
41AC
Daylight Savings Time (DST) Start Day Instance
41AD
Daylight Savings Time (DST) Start Hour
41AE
Daylight Savings Time (DST) Stop Month
41AF
Daylight Savings Time (DST) Stop Day
41B0
Daylight Savings Time (DST) Stop Day Instance
41B1
Daylight Savings Time (DST) Stop Hour
Fault Report Commands (Read/Write Command)
41B2
Fault Reports Clear Data Command
Oscillography (Read/Write Setting)
41C0
Oscillography Number of Records
41C1
Oscillography Trigger Mode
41C2
Oscillography Trigger Position
41C3
Oscillography Trigger Source
41C4
Oscillography AC Input Waveforms
41D0
Oscillography Analog Channel n (16 items)
4200
Oscillography Digital Channel n (63 items)
Trip and Alarm LEDs (Read/Write Setting)
4260
Trip LED Input FlexLogic Operand
4261
Alarm LED Input FlexLogic Operand
User Programmable LEDs (Read/Write Setting) (48 modules)
4280
FlexLogic™ Operand to Activate LED
4281
User LED type (latched or self-resetting)
4282
...Repeated for User-Programmable LED 2
4284
...Repeated for User-Programmable LED 3
4286
...Repeated for User-Programmable LED 4
4288
...Repeated for User-Programmable LED 5
428A
...Repeated for User-Programmable LED 6
428C
...Repeated for User-Programmable LED 7
428E
...Repeated for User-Programmable LED 8
4290
...Repeated for User-Programmable LED 9
B-20
RANGE
---
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0.00 to 99.99
0 to 1
0 to 4294967295
1 to 65535
0 to 235959
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
–24 to 24
0 to 1
0 to 11
0 to 6
0 to 4
0 to 23
0 to 11
0 to 6
0 to 4
0 to 23
0 to 1
1 to 64
0 to 1
0 to 100
0 to 65535
0 to 4
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
D30 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F072
---
1
F134
---
1
F134
---
1
F134
---
1
F134
---
1
F134
---
1
F134
---
0.01
F001
---
1
F102
---
1
F003
---
1
F001
---
1
F050
---
1
F051
---
1
F052
---
1
F114
---
1
F102
hours
0.5
F002
---
1
F102
---
1
F237
---
1
F238
---
1
F239
---
1
F001
---
1
F237
---
1
F238
---
1
F239
---
1
F001
---
1
F126
---
1
F001
---
1
F118
0 (Auto. Overwrite)
%
1
F001
---
1
F300
---
1
F183
2 (16 samples/cycle)
---
1
F600
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F127
DEFAULT
0
0 (Fail)
0 (Fail)
0 (Fail)
0 (Fail)
0 (Fail)
0 (Fail)
0
0 (Disabled)
0
123
0
0
0
0 (None)
0 (Disabled)
0
0 (Disabled)
0 (January)
0 (Sunday)
0 (First)
2
0 (January)
0 (Sunday)
0 (First)
2
0 (No)
5
50
0
0
0
0
0
0
1 (Self-Reset)