Xstatus Systemunit Notifications Notification [N] Type; Xstatus Systemunit Productid; Xstatus Systemunit Hardware Monitoring Fan [N] Status; Xstatus Systemunit Hardware Temperature - Cisco TelePresence SX20 Codec Reference Manual

Application programming interface (api)
Hide thumbs Also See for TelePresence SX20 Codec:
Table of Contents

Advertisement

Cisco TelePresence SX20 Codec
Introduction

xStatus SystemUnit Hardware Monitoring Fan [n] Status

The feedback shows the speed (rpm) for the specified fan.
Value space of the result returned:
String
Example:
xStatus SystemUnit Hardware Monitoring Fan 1 Status
*s SystemUnit Hardware Monitoring Fan 1 Status: "locked on 1096 rpm"
** end

xStatus SystemUnit Hardware Temperature

Shows the current maximum temperature (degree Celsius) measured in the codec/system.
Value space of the result returned:
String
Example:
xStatus SystemUnit Hardware Temperature
*s SystemUnit Hardware Temperature: "64.0"
** end

xStatus SystemUnit Notifications Notification [n] Text

Lists text related to important system notifications. Notifications are issued e.g. when a system
was rebooted because of a software upgrade, or when a factory reset has been performed.
All the notifications can be removed from the list by issuing the xCommand SystemUnit
Notifications RemoveAll command.
Value space of the result returned:
String
Example:
xStatus SystemUnit Notifications Notification 1 Text
*s SystemUnit Notifications Notification 1 Text: "OK"
** end
SX20 Codec API Reference Guide CE8.3, JANUARY 2017.
D15316.05
About the API
xConfiguration
xCommand

xStatus SystemUnit Notifications Notification [n] Type

Lists the system notification types. Notifications are issued e.g. when a system is rebooted
because of a software upgrade, or when a factory reset is performed.
FactoryResetOK: This value is returned after a successful factory reset.
FactoryResetFailed: This value is returned after a failed factory reset attempt.
SoftwareUpgradeOK: This value is returned after a successful software upgrade.
SoftwareUpgradeFailed: This value is returned after a failed software upgrade attempt.
RebootRequired: This value is returned when a reboot is required.
Other: This value is returned for any other notifications.
All the notifications can be removed from the list by issuing the xCommand SystemUnit
Notifications RemoveAll command.
Value space of the result returned:
FactoryResetOK, FactoryResetFailed, SoftwareUpgradeOK, SoftwareUpgradeFailed,
RebootRequired, Other
Example:
xStatus SystemUnit Notifications Notification 1 Type
*s SystemUnit Notifications Notification 1 Type: SoftwareUpgradeOK
** end

xStatus SystemUnit ProductId

Shows the product identity.
Value space of the result returned:
String
Example:
xStatus SystemUnit ProductId
*s SystemUnit ProductId: "Cisco TelePresence Codec SX80"
** end
189
API Reference Guide
xStatus
xStatus
Appendices
Copyright © 2017 Cisco Systems, Inc. All rights reserved.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents