Honeywell AlarmNet 7845i-GSM Installation And Setup Manual page 31

Internet communication
Hide thumbs Also See for AlarmNet 7845i-GSM:
Table of Contents

Advertisement

If Lynx Panic is enabled, then skip to Prompt 43: "Rpt Zn3 ONLY if Armed."
PROMPTS
Zn3 Trigger Type
39
(V+)_
Invert Zn3 Y/N
40
(N)_
Restore Zn3 Y/N
41
(Y)_
Delay Zn3 (secs)
42
(00)
Rpt Zn3 ONLY if
43
Armed (N)_
Zn4 Trigger Type
44
(V+)_
45
Invert Zn4 Y/N
(N)_
46
Restore Zn4 Y/N
(Y)_
Delay Zn4 (secs)
47
(00)
Rpt Zn4 ONLY if
48
Armed (N)_
Zn5 Trigger Type
49
(V+)_
Invert Zn5 Y/N
50
(N)_
Restore Zn5 Y/N
51
(Y)_
Delay Zn5 (secs)
52
(00)_
Rpt Zn5 ONLY if
53
Armed (N)_
ZONE
4204/
ENTRY
TRIG.
2-4204
• (EOLR)
• (V+)
• (V–)
[Y], [N]
[Y], [N]
[01-15]
[00] = no delay
[Y], [N]
• (EOLR)
• (V+)
• (V–)
[Y], [N]
[Y], [N]
[01-15]
[00] = no delay
[Y], [N]
2-
4204
only
• (EOLR)
• (V+)
• (V–)
[Y], [N]
2-
[Y], [N]
4204
only
[01-15]
2-
4204
[00] = no delay
only
[Y], [N]
2-
4204
only
Section 3: Programming the 7845i-GSM
OPTIONS
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
Inverts the alarm and normal states of the zone
3 trigger; otherwise uses normal input signal.
Enables restore reporting for zone 3.
Defines the reporting delay in seconds for zone 3.
Reports alarms on zone 3 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 3.
4204 mode: If any zone is programmed to
"Report Only if Armed," skip to Prompt 54:
"Enable Zn6."
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
Inverts the alarm and normal states of the zone
4 trigger; otherwise uses normal input signal.
Enables restore reporting for zone 4.
Defines the reporting delay in seconds for zone 4.
Reports alarms on zone 4 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 4.
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
Inverts the alarm and normal states of the zone
5 trigger; otherwise uses normal input signal.
Enables restore reporting for zone 5.
Defines the reporting delay in seconds for zone 5.
Reports alarms on zone 5 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 5.
DESCRIPTION