Internet Communication Module 7845i-GSM Installation and Setup Guide
PROMPTS
Open/Close Zone
30
(0)_
Zn1 Trigger Type
31
(V+)_
Restore Zn1 Y/N
32
(Y)_
Delay Zn1 (secs)
33
(00)_
Rpt Zn1 ONLY if
34
Armed (N)_
Invert Zn2 Y/N
35
(N)_
Restore Zn2 Y/N
36
(Y)_
Delay Zn2 (secs)
37
(00)_
Rpt Zn2 ONLY if
38
Armed (N)_
3-14
4204/
ZONE
ENTRY
2-4204
TRIG.
OPTIONS
Enter the zone number to be used for open/close
Zone Trig: [3-7]
(arm/disarm) reports.
4204: [1-4]
This zone assignment must be unique from the
2-4204: [1-8]
telco zone selected in Prompt 29.
Zone Trigger Mode: If any zone is programmed
[0] = not used
for "report only if armed," zone 7 cannot be
used as an open/close zone. If Lynx Panic is
enabled, zone 3 cannot be used.
4204 Mode: If any zone is programmed for
"report only if armed," zone 4 cannot be used
as an open/close zone.
2-4204 Mode: If any zone is programmed for
"report only if armed," or if tamper is enabled,
zone 8 cannot be used as an open/close zone.
NOTE: Connect an open/close (arm/disarm)
trigger (or relay output) from the control panel to
the open/close zone.
• (EOLR)
Selects the triggering method for this zone input.
• (V+)
Press the [space] key to scroll through choices.
• (V–)
[Y], [N]
Enables restore reporting for zone 1.
[01-15]
Defines the reporting delay in seconds for zone 1.
[00] = no delay
[Y], [N]
Report alarms on zone 1 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; or zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 1.
[Y], [N]
Inverts the alarm and normal states of the zone
2 trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 2.
[01-15]
Defines the reporting delay in seconds for zone 2.
[00] = no delay
[Y], [N]
Reports alarms on zone 2 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 2.