Dlp- G90 Verify An Ad-Xb-Xx.x Pass-Through Connection Power - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

DLP-G90 Verify an AD-xB-xx.x Pass-Through Connection Power
Step 14
(Optional) Perform one of the following:
Return to your originating procedure (NTP).
Step 15
DLP-G90 Verify an AD-xB-xx.x Pass-Through Connection Power
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Verify the east AD-xB-xx.x band TX power:
Step 1
a.
b.
c.
d.
Step 2
Verify the west AD-xB-xx.x card RX and TX power:
a.
b.
c.
d.
e.
Step 3
Verify the band RX port on the east AD-xB-xx.x card:
a.
b.
c.
Step 4
Return to your originating procedure (NTP).
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
4-50
If an OSCM card is installed, connect a power meter to LINE TX port on the card front panel and
verify that the east OPT-BST amplifier is turned on by the pass-through wavelength.
If an OSC-CSM card is installed, complete the
task on page 4-44
for the east OSC-CSM card.
This task verifies an AD-xB-xx.x pass-through connection.
None
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Superuser
Display the east AD-xB-xx.x card in card view.
Click the Provisioning > Optical Band > Parameters tabs.
Change the Admin State of the BAND TX (east-to-west) port related to the wavelength selected on
the tunable laser to OOS,MT (ANSI) or Locked,maintenance (ETSI). Click Apply.
Verify that the BAND TX port Power value is higher than the default no-power value of –30 dBm.
Display the west AD-xB-xx.x card in card view.
Click the Provisioning > Optical Band > Parameters tabs.
Verify that the Power value of the BAND RX (east-to-west) port is higher than the default no-power
value of –30 dBm.
Change the Admin State of the BAND TX (west-to-east) port related to the wavelength selected on
the tunable laser to OOS,MT (ANSI) or Locked,maintenance (ETSI). Click Apply.
Verify that the BAND TX port Power value is higher than the default no-power value of –30 dBm.
Display the east AD-xB-xx.x card in card view.
Click the Provisioning > Optical Band > Parameters tabs.
Verify that the Power value of the BAND RX (west-to-east) port is higher than the default no-power
value of –30 dBm.
Chapter 4
Perform Node Acceptance Tests
"DLP-G84 Verify the OSC-CSM Incoming Power"
September 2005

Advertisement

Table of Contents
loading

Table of Contents