W
iring diagram
Fig. D-3E
Support Unit
Power supply
circuit
Put Power supply
circuit into the above
illustrated position.
Support unit's Lead wire (orange)
Connect Insulated connector to
Switch terminal 2, keeping it
away from the Boss.
Switch terminal 2
Insulated connector
RP1800F with LED Job Light
Wiring in Motor housing
on top side (Rear cover side)
Support unit's Lead wire (black)
RP1800F with LED Job Light
Wiring in Grip (R)
Boss
Lead wire holder
When putting Support unit's Lead wires
into Lead wire holders, put them as follows.
* Support unit's Lead wire (black)
into Lead wire holder of outside
* Support unit's Lead wire (orange)
into Lead wire holder of inside