Improvement of the reaction time of overload output signal

Processing cycle of overload advance notice signal (OL, OL2) is selectable from 40ms / 2ms by C901. Please
select appropriate processing cycle for your application.
C902 and C903 are available only when C901 = 01.
Overload signal is turned off when output current is lower than
"overload warning level (C041 / C241, C111), and its hysteresis can be specified by overload advance notice
signal hysteresis (C903)".
(If C903 is bigger than overload warning level, overload advance notice signal is turned off when motor
stops.)
If overload advance notice signal repeats switching on/off in short time due to the instability of output
current, please adjust C902 and C903. Because a response changes depends on C902 and C903 value, please
be careful.
NOTE:. Parameters marked with " " in A column can set even in inverter running and marked with " "
NOTE
NOTE
NOTE
cannot set in inverter running. Parameters marked with " " in B column can set even in inverter
running and marked with " " cannot set in inverter running when in the high level access mode, which
means that b031 is set to "10".
Func.
Func.
Func.
Func.
Code
Code
Code
Code
C901
C901
C901
C901
Processing cycle of overload
advance notice signal select
C902
C902
C902
C902
Filter time constant for
overload advance notice
signal
C903
C903
C903
C903
Overload advance notice
signal hysteresis
Timing chart of overload advance notice signal (2msec)
Output current
Overload warning level
(C041/ C241, C111)
Overload advance notice signal
Name
Name
Name
Name
00...40 msec.
00
00
00
0 0 0 0 1 1 1 1 ...2 msec.
It effects detection of output
current that is used for judgement
of overload advance notice signal,
range is 0 to 9999 msec.
The ratio for the rated current of
each INV mode. It effects turning
off of overload advance notice
signal,
range is 0.00 to 50.00 %
ON
Table Ver.3.1-1
Description
Description
Description
Description
A A A A B B B B
ON
Fig. Ver.3.1-1
Modbus s s s register
Modbu
register
Modbu
Modbu
register
register
Initial data
Initial data
Initial data
Initial data
number
number
number
number
00
14f0h
0
14f1h
10.00
14f2h
Hysteresis (C903)
Resolution
Resolution
Resolution
Resolution
-
1 [ms]
0.01 [%]