Figure 47 – ST 700 Basic Transmitter - Inline Model Mounted to an Optional Bracket
7. Loosen the set screw on the outside neck of the Transmitter one (1) full turn.
8. Rotate the Electronics housing a maximum of 180
you require, and tighten the set screw using a 4mm metric socket head wrench. See the
following example and Figure 48.
Example: Rotating the Electronics Housing
Figure 48 – ST 700 Basic Transmitter - Rotating the Electronics Housing
The mounting position of AP models STA725, STA745, STA72S, STA74S and STA77S
becomes critical as the Transmitter spans become smaller. A maximum zero shift of
2.5mmHg for these models can result from a mounting position that is rotated 90o from the
vertical.
A typical zero-shift of 0.12mmHg or 0.20 inH
the vertical.
Revision 8.0
2
ST 700 SmartLine Pressure Transmitters User's Manual
o
left or right from the center to the position
O can occur for a five (5)-degree rotation from