Verification Of The Distance Between Spark Plug Electrode; Verification Of The Position Sensor Crankshaft; Verification Of Operation Starter - Yamaha FZ-16 Service Manual

Hide thumbs Also See for FZ-16:
Table of Contents

Advertisement

• Tester positive probe
High voltage cable
• Tester negative probe
land
2
c. Measuring the resistance of the secondary coil.
VERIFICATION OF THE DISTANCE BETWEEN
SPARK PLUG ELECTRODE
1. Check:
• Distance between electrodes of the spark plug
Out of specification Make the solution
of power system problems,
starting with step 5. See
"TROUBLESHOOTING" on page
7-3.
Minimum distance between electrodes
from 0.8 to 0.9 mm plug
NOTE:
If the distance between electrodes of the spark plug is
within specifications, the circuit
ignition system is working
normally.
a. Disconnect the spark plug cap from spark plug.
b. Connect the dynamic spark tester "1"
as shown.
Dynamic spark tester
1. Dynamic spark tester
2. Spark plug cap
c. Turn the main switch to "ON"
and the engine stop switch to position
! ".
d. Measuring the distance from spark ignition "a".
e. Start the engine by pushing the switch
Start! "
1
7-40
ELECTRICAL COMPONENTS
VERIFICATION OF THE POSITION SENSOR
CRANKSHAFT
1 .. Disconnect:
• coupler crankshaft position sensor
(From the wiring harness)
2.Check:
• Reliability of crankshaft position sensor
Off-specification position sensor
Crankshaft / stator assembly.
Position sensor resistance
Ù 192-288 crankshaft at 20 ° C (68 ° F)
a. Connect the multimeter to the sensor coupler
crankshaft position, as shown.
Multimeter
• Tester positive probe
blue / yellow "1"
• Tester negative probe
green "2"
1
b. Measuring the resistance of position sensor
crankshaft.
VERIFICATION OF OPERATION
STARTER
1.Check:
• Operation of starter
Do not work troubleshooting
electric start, beginning with the
Step 4. See "SOLUTION
Problems "on page 7-9.
LY G
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents