The example shows the following time program:
Set-
point
Time
1
6:00 – 9:00
2
9:00 – 12:00
3
12:00 – 14:00
4
14:00 – 17:00
5
17:00 – 22:00
6
22:00 – 6:00
i
An overview of the program structure is shown on the
last page of these instructions.

Week program

You can adjust the time program to your personal weekly
routine. You have the following options to this purpose:
• Separate time programs for weekdays Mo – Fr (1 – 5)
and weekend Sa – Su (6 – 7)
• One time program for the days of the week Mo – Su
(1 – 7)
• A different time program for each day of the week Mo,
Tu, We, Th, Fr, Sa, Su (1, 2, 3, 4, 5, 6, 7)
i
We recommend that you write down your time pro-
gram before beginning programming.
Setting the time program
Selecting weekdays
1. Press the PROG button.
is displayed.
comfort 1
2. Turn the adjustment dial clockwise until
displayed.
 OK 
3. Press the
button and use the adjustment dial to
select the desired weekdays for your time program:
,
,
mo - fr
sa - su
day off
4. Confirm the selected weekdays with the
The temperature as well as the beginning and end of
the first setpoint, e.g.:
Temperature
20 °C (Comfort temperature 1)
16 °C (Setback temperature)
20 °C (Comfort temperature 1)
16 °C (Setback temperature)
22 °C (Comfort temperature 2)
16 °C (Setback temperature)
program
,
,
, ...,
mo - su
mo
tu
su
 OK 
i
• The end of a setpoint is also the beginning of the
next setpoint.
• You can use the adjustment dial to change from
one setpoint to another and thus view the setting
of all the programmed setpoints.
• Only the programmed setpoints are displayed.

Editing setpoints

1. In order to edit the displayed setpoint press the
button.
The temperature display flashes.
2. Use the adjustment dial to select the desired
temperature (Comfort temperature 1, 2 or Setback
temperature) for the selected setpoint and confirm
with  OK .
The beginning of the selected setpoint flashes.
i
The time scale for programming of the setpoints
begins at 3:00 in the morning and ends at 2:50 on the
following day.
3. Use the adjustment dial to set the desired beginning
for the selected setpoint and confirm with  OK .
The end of the selected setpoint flashes.
4. Use the adjustment dial to set the desired end of the
selected setpoint and confirm with  OK .
is displayed briefly. Subsequently the
saved
temperature as well as the beginning and end of the
setpoint are displayed.
5. For the further setpoints also select the temperature
as well as the beginning and end of the setpoint as
described in Steps 1 to 5.
i
• A setpoint is not saved until the temperature,
beginning and end have been confirmed with
the
is
• If a setpoint is not required, select the setting
--.-
Editing further weekdays
or
1. When all the setpoints have been edited, use the
PROG button to select the weekdays.
button.
2. Edit the setpoints for the next weekdays.
3. After all the required weekdays have been set, exit
programming with the AUTO button.
The radiator controller operates immediately in
automatic mode with the set time program.