Cable connection
i
For further information also refer to the
documentation for HCW23, RF20 and HCA30.
fConnect the ACS90 cable as follows to the external
sensor and window contact:
HCW23 setpoint adjuster
white NTC
green TW/F
ACS90
black GND
RF20 room sensor
white NTC
ACS90
black GND
green TW/F
RF20 room sensor and floating HCA30 window contact
white NTC
ACS90
black GND
green TW/F
HCA30 floating window contact
white NTC
ACS90
black GND
green TW/F
Connecting the cable with the HR90 radiator
controller
1.
1. Remove the side cover from the radiator controller.
2. Insert the cable ASC90 into the HR90 radiator
controller.
The radiator controller recognizes the connected
sensor / window contact automatically.
1
2
HCW23
3
2.

5. Operation

Standard time program (factory setting)
In automatic mode, the radiator controller automatically
controls the room temperature in accordance with the
stored time program.
Week program 1: At home all day
Factory preset time program is set for each day of the
week Mo – Su (1 – 7):
20 °C
Lowering/
Saving
16 °C
Setpoint 1
Set-
point
Time
1
6:00 – 22:00
2
22:00 – 6:00
i
• Two further week programs are stored in the
radiator controller. Further information is available
in Section 9.
• You can also adapt one of the stored week
programs to your individual requirements, see
Section 8.
Adapting the temperature temporarily
If you want to change the temperature specified by the
time program temporarily:
fSet your desired temperature using the adjustment
dial.
The change remains in effect until the next setpoint.
i
The process of changing the temperatures
permanently is described in Section 7.
6
Heating
Temperature
20 °C (Comfort temperature 1)
16 °C (Setback temperature)
Setpoint 2