Value Range
INS: The card is in service.
OUS: The card is out of service.
Fault: The card is pulled out from the sub-slot, or is not communicating with the PBX.
Programming Guide References
4.7.1 Slot [1-1]
Feature Guide References
None
For Output (EIO)—Device Type
Selects the type of connected output device (for output ports only).
Default
Relay
Value Range
Relay, Ringer
Programming Guide References
4.7.1 Slot [1-1]
Feature Guide References
1.15.8 External Relay Control
For Sensor (EIO)—Input Signal Decision Time
Specifies the minimum duration of continuous input from the triggered sensor before the PBX recognizes
the input and makes a sensor call.
Default
1024 ms
Value Range
32 × n (n=2–255) ms
Programming Guide References
4.7.1 Slot [1-1]
Feature Guide References
1.15.7 External Sensor
For Sensor (EIO)—Input Signal Detection Reopening Time
Specifies the length of time after the sensor has been triggered during which any further input from the
sensor will be ignored.