Overview of Alarms
of instructions (nesting). Example: N10 DEFINE MACRO1 AS G01 G91 X123 MACRO2
F100
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Nested macros must be replaced by the full program information.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12260
Channel %1 block %2 too many initialization values specified %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions:
In the initialization of an array (array definition and value assignments to individual array
elements) there are more initialization values than array elements. Example: N10 DEF
INT OTTO[2,3]=(..., ..., {more than 6 values})
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Check the NC program to establish whether:
1. During array definition the number of array elements (n,m) was indicated correctly
(DEF INT FIELDNAME[n,m] e.g. an array with 2 lines and 3 columns: n=2, m=3). 2. Dur-
ing initialization the value assignments have been made correctly (values of the individual
field elements separated by comma, decimal point for variables of the type REAL).
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12261
Channel %1 block %2 initialization of %3 not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions:
Frame type variables cannot be initialized in the definition. Example: DEF FRAME LOC-
FRAME = CTRANS(X,200)
Equally, no default values can be programmed for axes in the program run when initializ-
ing fields by SET.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
IPerform initialization in separate block in the execution part of the program: DEF FRAME
LOCFRAME LOCFRAME = CTRANS(X,200)
When using for axis variables:
Replace DEF AXIS AXIS_VAR [10] AXIS_VAR [5] = SET (X, , Y) by: DEF AXIS
AXIS_VAR [10] AXIS_VAR [5] = X AXIS_VAR [7] = Y
If REDEF ... INIRE, INIPO, INICF, PRLOC changes the behavior of a GUD, LUD etc.,
then the machine data $MN_DEFAULT_VALUES_MEM_MASK must equal 1.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
2-150
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005