Siemens SINUMERIK 840D sl Series Diagnostics Manual page 770

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
Cause:
After initializing the pole position using track C/D or using Hall signals, the zero mark was
detected outside the permissible range. Fine synchronization was not carried-out.
The deviation may be up to 18 ° mechanical or up to 60 ° electrical.
Fault value (r0949, decimal):
Normalization: 32768 = 180 °
High word:
Mechanical zero mark position determined.
If the initialization via a track C/D is selected in p0404, then it is checked whether the zero
mark occurs in an angular range of +/-18 ° mechanical.
Low word:
Deviation of the zero mark from the expected position as electrical angle.
If the correction of the commutation position with the zero mark is selected in p0404, then
a difference of a maximum of +/- 60 ° electrical is permitted.
Remedy:
- check that the encoder cables are routed in compliance with EMC.
- check the plug connections.
- if the Hall sensor is used as an equivalent for track C/D, check the connection.
- check the connection of track C or D.
- replace the encoder or encoder cable.
233131
<location>Encoder 3: Deviation, position incremental/absolute too large
Reaction:
A_INFEED: NONE
SERVO: ENCODER (DCBRAKE, NONE, OFF1, OFF2, OFF3, STOP1, STOP2)
Acknowledge:
READY
Cause:
When cyclically reading the absolute position, an excessively high deviation to the
incremental position was detected. The absolute position that was read is rejected.
Limit value for the deviation:
- EnDat encoder: Is supplied from the encoder and is a minimum of 2 quadrants (e.g. EQI
1325 > 2 quadrants, EQN 1325 > 50 quadrants).
- other encoders: 15 pulses = 60 quadrants.
Fault value (r0949, decimal):
Deviation in quadrants (1 pulse = 4 quadrants).
Remedy:
- check that the encoder cables are routed in compliance with EMC.
- check the plug connections.
- replace the encoder or encoder cable.
- check whether the coding disk is dirty or there are strong ambient magnetic fields.
233150
<location>Encoder 3: Initialization error
Reaction:
A_INFEED: NONE
SERVO: ENCODER (DCBRAKE, NONE, OFF1, OFF2, OFF3, STOP1, STOP2)
Acknowledge:
READY
Cause:
Encoder functionality selected in p0404 is not operating correctly.
Fault value (r0949, hexadecimal):
The fault value is a bit field. Every set bit indicates functionality that is faulted.
The bit assignment corresponds to that of p0404 (e.g. bit 5 set: Error track C/D).
Remedy:
- Check that p0404 is correctly set.
- check the encoder type used (incremental/absolute value) and for SMCxx, the encoder
cable.
- if relevant, note additional fault/error messages that describe the fault in detail.
233405
<location>Encoder 3: Encoder evaluation temperature too high
Reaction:
NONE (DCBRAKE, OFF1, OFF2, OFF3, STOP1, STOP2)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The encoder evaluation for a motor with DRIVE-CLiQ has detected an excessively high
temperature.
The fault threshold is 125 ° C.
Alarm value (r2124, decimal):
Measured board/module temperature in 0.1 °C.
2-770
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved