4.
3.6.4

Delete a device

This option is presented when the RFID of a selected point has already been configured. When
you choose this option, the control panel sets the selected point back to its default condition.
The RFID is removed from the receiver's database.
3.7

Configure Wireless Devices from RPS

In addition to the Installer Phone Menu, you may use RPS to configure an Easy Series control
panel with RADION support. To configure RADION wireless points, specify the following
information for each point:
Since Wireless Alarm Inputs is only available in "Expert Mode", you must use Expert Mode to
properly configure the Easy Series control panel for RADION wireless devices.
The following table shows the correlation between the current RPS Device Type values and
the RADION Device Types.
1.
2.
3.
4.
When setting up an Easy Series control panel to use RADION transmitters, only select from the
RPS device types listed in the table below.
RPS device type
PIR motion detector
Dual motion detector
Wireless device type 3
Smoke detector
Door Window contact sensor
Inertia sensor
Glass break sensor
Wireless Recessed Point
Wireless Bill Clip
2014.09 | 01 | F.01U.306.221
To continue, press [1]. If you choose to continue, the control center announces "Please
wait". During this time, the RFID is saved in the database and configured in the RADION
receiver.
To try again, press [2]. If you choose to try again, the control panel ignores the RFID that
was discovered and returns to the "discovering devices" message.
Device Type
Point Type
Wireless Point ID
Wireless Alarm Inputs
Once the device type has been selected in RPS, enter the Wireless Point ID and Point
Type via the "wizard" dialog.
Enter the RFID for the point as specified in the product packaging.
Select the desired Point Type from the drop-down menu.
Enter an appropriate value in the Wireless Alarm Inputs column.
System Reference Guide
RADION transmitter
PIR detector (RFPR-12)
PIR ceiling mount detector
(RFPR-CE)*
PIR curtain detector (RFPR-
C12)
Motion detector (RFDL-11)
Repeater (RFRP)
Smoke detector (RFSM)
Universal transmitter (RFUN)
Inertia sensor (RFIN)*
Glassbreak detector (RFGB)
Recessed door/window
contact (RFDW-RM)
Bill trap (RFBT)
Easy Series Control Panel
Wireless alarm inputs
Motion
Motion
None
Smoke
Wired or magnet
Inertia or magnet
Glass break
Magnet
Magnet