Bosch ICP-EZM2 Installer's Manual page 70

Intrusion control panel
Hide thumbs Also See for ICP-EZM2:
Table of Contents

Advertisement

Easy Series (ICP-EZM2) | Installer Guide | 7.0 Reference Materials
Quick Reference
Refer to the following table for programmable features, shipping defaults, and recommended programming
that comply with the ANSI/SIA CP-01 False Alarm Reduction standard.
The system test button tests all points, all outputs, the control panel, and the communicator. Refer to Section 5.0
System Test on page 56 for more information.
Paragraph
Number in
ANSI/SIA CP-01
Feature
4.2.2.1
Exit Time
4.2.2.2
Progress
Annunciation/
Disable for Silent Exit
4.2.2.3
Exit Time Restart
4.2.2.5
Auto Stay Arm on
Unvacated Premises
4.2.4.4
Exit Time and
Progress
Annunciation/
Disable for Remote
Arm
4.2.3.1
Entry Delay(s)
4.2.5.1
Abort Window for
Non-fire Zones
4.2.5.1
Abort Window Time
for Non-fire Zones
4.2.5.1.2
Abort Annunciation
4.2.5.4.1
Cancel Annunciation
Duress Feature
4.2.6.1 and
4.2.6.2
4.3.1
Cross Zoning
4.3.1
Programmable Cross
Zoning Time
4.3.2
Swinger Shutdown
4.3.2
Swinger Shutdown
Disable
4.3.3
Fire Alarm
Verification
4.5
Call Waiting Cancel
1
Programming at installation site might be subordinate to other UL requirements for the intended application.
2
Combined Entry Delay and Abort Window should not exceed 1 minute.
3
If the cross zone timer ends and a second cross zone point is not faulted, the system sends an intrusion alarm unverified report.
70
Requirement
Range
Required
For full or auto arming: 45 sec to
(programmable)
2 min (255 sec max)
Allowed
Individual control centers can be
disabled.
Required option
For re-entry during Exit Time
Required option
If no exit after full arm
(except for
remote arm)
Allowed option
Can be disabled for remote arm
(for remote arm)
Required
30 sec to 4 min
(programmable)
Required option
Can be disabled by zone or zone
type
Required
15 sec to 45 sec
(programmable)
Required option
Annunciate that no alarm was
transmitted
Required option
Annunciate that a Cancel was
transmitted
Allowed option
No 1+ derivative of another user
code; no duplicates of other user
codes
Required option
Programming needed
Allowed
Can program
Required
For all non-fire zones, shut down at
(programmable)
one or two faults
Allowed
For non-police response zones
Required option
Depends on control panel and
sensors
Required option
Depends on user phone line
Bosch Security Systems, Inc. | 5/07 | F01U025147-01
Shipping
Default
60 sec
All control
centers
enabled.
Enabled
Enabled
Enabled
2
30 sec
Enabled
2
30 sec
Enabled
Enabled
Disabled
Disabled
Per
manufacturer
One fault
Enabled
Disabled
Disabled
Recommended
1
Programming
60 sec
All control
centers enabled.
Enabled
Enabled
Enabled
2
At least 30 sec
Enabled
(all zones)
2
At least 15 sec
Enabled
Enabled
Disabled
Enabled and two
or more zones
programmed
Per walk path in
protected
premises
One fault
Enabled
(all zones)
Enabled unless
sensors can self-
verify
Enabled if user
has call waiting