23 IGNITION SYSTEM
245
EN
+
m
3
2
1
<r
600894-10
R01418-10
Stator winding I - check short circuit to ground (terminal 31).
Measure the resistance between the specified points.
Stator, connector EN pin 1 - Measuring point Ground (-)
Q
Resistance
Q
oo
If the indicated value does not correspond to the setpoint value:
- Change the stator.
EN
+
J
3
2
1
R01418-10
600894-10
Stator winding II - check short circuit to ground (terminal 31).
Measure the resistance between the specified points.
Stator, connector EN pin 2 - Measuring point Ground (-)
Q
Resistance
Q
oo
If the indicated value does not correspond to the setpoint value:
- Change the stator.
EN
+
3
2
1
600894-10
R01418-10
Stator winding III - check short circuit to ground (terminal 31).
Measure the resistance between the specified points.
Stator, connector EN pin 3- Measuring point Ground (-)
Q
Resistance
Q
oo
» If the indicated value does not correspond to the setpoint value:
- Change the stator.
Start the motorcycle to check the function. (iS p. 14)
Stator winding measurement I - check the voltage.
Measure the voltage between the specified points.
Stator, connector EN pin 1 - Stator, connector EN pin 2
EN
V
Info
The results of the measurements on the individual coils must not deviate
noticeably from each other.
I
3
2
1
AC generator