40
en | Installing
Figure 4.13: Closing the extension case
Notice!
Risk of damage to equipment
If excessive force is required to close the front cover then it is probably incorrectly hooked
into the back cover. In such cases the display 'Dialog' button in the front cover will be
misaligned and will not function correctly.
4.5
Cabling
Notice!
Risk of malfunction
The cables used in the AMC2-4R4 access control system are not prone to electrical
interference. However, you should avoid routing cables close to heavy load switching cables
and equipment. If this is unavoidable, cross the cable at right angles every 1 to 2 m (3 to 6 ft)
to reduce interference.
Notice!
Risk of malfunction
The cables used in the AMC2-4W access control system are not prone to electrical
interference. However, you should avoid routing cables close to heavy load switching cables
and equipment. If this is unavoidable, cross the cable at right angles every 1 to 2 m (3 to 6 ft)
to reduce interference.
4.5.1
Conductor data for power to AMC2
With the calculation below you can find out which cable type must be used. If you connect the
power supply and the AMC-device with the delivered cable set from the enclosure the
calculation is not necessary.
2020-01 | V02 |
Installation manual
Access Modular Controller 2
Bosch Access Systems V.B.