Epson Stylus Photo PX700FW Service Manual page 198

Hide thumbs Also See for Stylus Photo PX700FW:
Table of Contents

Advertisement

Epson Artisan 800/Epson Stylus Photo PX800FW/TX800FW/Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
Lift the Hinge on the right side in the direction of the arrow (1), and slide the
7.
Scanner Unit in the direction of the arrow (2), and remove it.
Figure 4-206. Removing the Scanner Unit (3)
DISASSEMBLY/ASSEMBLY
Scanner Unit
Disassembly/reassembly procedures specific to Artisan 700/PX700W/TX700W
https://www.manualsbooks.com
When installing the Scanner Unit, follow the procedure below.
Align and insert the dowel of the Scanner Unit to the
positioning hole of the printer (Left inside).
Align and insert the rib of the Scanner Unit to the groove of
the Hinge.
Left
Dowel
Hole
Figure 4-207. Installing the Scanner Unit (1)
While aligning and inserting the rib of the Scanner Unit to
the groove of the Hinge, secure them with the screw (x1)
temporarily with the screw holes aligned as shown in
4-205. It is recommended to prepare a pillow-shaped
supporter to keep this position. (See
Revision C
Rib of the Scanner Unit
Right
& groove of the Hinge
inside
Fig.
Fig.
4-10.)
(Continued to the next page.)