Epson Stylus Photo PX700FW Service Manual page 182

Hide thumbs Also See for Stylus Photo PX700FW:
Table of Contents

Advertisement

Epson Artisan 800/Epson Stylus Photo PX800FW/TX800FW/Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
Release the ribs (Artisan 800/PX800FW/TX800FW: x4, Artisan 700/
1.
PX700W/TX700W: x3) that secure the Scanner Cable Cover to the Scanner
Lower Housing, and remove the Scanner Cable Cover from the Scanner
Lower Housing in the direction of the arrow.
Pull out the Ferrite Core from the Scanner Carriage FFC.
2.
Artisan 800/PX800FW/TX800FW
side
Ferrite Core
Scanner Cable Cover
Scanner Carriage FFC
Figure 4-168. Removing the Carriage Unit (1)
DISASSEMBLY/ASSEMBLY
Artisan 700/PX700W/TX700W
side
Ferrite Core
Scanner Carriage
FFC
Rib
Disassembly Procedures
https://www.manualsbooks.com
Turn the Combination Gear 12.1, 11.3 in the direction of the arrow, and move
3.
the Scanner Carriage Unit to the center.
Take extra care not to contaminate the Scanner Timing Belt with
grease on the rail of the Lower Scanner Housing.
Remove the Driven Pulley and Combination Gear12.1, 11.3 from the Scanner
4.
Lower Housing, and remove the Scanner Timing Belt.
Scanner Carriage Unit
Driven Pulley
Scanner Timing Belt
Figure 4-169. Removing the Scanner Carriage Unit (2)
Revision C
Combination Gear12.1, 11.3