Connecting Stations; Cautions For Connecting Stations; Table 7.1 Distance Between Stations And The System - Samsung OfficeServ 7200 Installation Manual

Hide thumbs Also See for OfficeServ 7200:
Table of Contents

Advertisement

CHAPTER 7.
Additional Equipment
This chapter describes how to connect various stations and additional equipment, such as
analog/digital phones, door phones and door locks, to the OfficeServ 7200.

7.1 Connecting Stations

7.1.1 Cautions for Connecting Stations

Take the following cautions when connecting stations.
Do not connect stations in weather conditions such as storm and lightning.
Do not connect stations in a humid area.
Comply with the manual of the station and with this manual when reconnecting
stations or changing connections.
Connect stations to a pair of #24 AWG or #26 AWG cables.
The distances between stations and the OfficeServ 7200 are as follows:
Digital phone
Analog phone
Door phone
AOM
SMT-R2000
© SAMSUNG Electronics Co., Ltd.
Connecting Stations and

Table 7.1 Distance Between Stations and the System

Station
OfficeServ 7200 Installation Manual
Distance
Maximum 400 m (for AWG #24)
Maximum 1 km (for AWG #24)
Maximum 400 m (for AWG #24)
Maximum 400 m (for AWG #24)
Maximum 100 m (for Ethernet cable)
7-1