Reference
For detail information on functions and characteristics of each Interface board, refer to
'OfficeServ 7200 System Description'.
Mounting the GSIMT
Only one GSIMT can be mounted per the cabinet. If you mount boards more than
the capacity limit, it may cause malfunction of the PSU due to overload.
Mounting the GPLIMT
Only one GPLIMT can be mounted per the cabinet. When using an external
rectifier, up to two boards can be mounted. If you mount boards more than the
capacity limit, it may cause malfunction of the PSU due to overload.
Mounting the OAS in 16 channels slot
If the OAS is mounted on one of 16 channels slot, no board can be mounted on
the other slot. If any board is mounted on the other slot, the board will not work.
(If the slot 1 is occupied with the OAS, the slot 2 should be empty. And if the slot 2
is occupied with the OAS, the slot 1 should be empty.)
3-26