CHAPTER 6.
This chapter describes how to connect C.O. lines to the OfficeServ 7200 after installation.

6.1 Line Conditions

Cautions for connecting C.O. lines are as follows:
Cables with AWG #24 or AWG #26 should be used as subscriber lines.
When wiring cables in high-humidity areas, remove moisture before wiring.
Cables should be handled carefully to prevent any changes or damages.
Subscriber lines should be kept indoors if possible.
High voltage power lines should not be wired near a subscriber line.
Leak resistance for C.O. lines connected to the OfficeServ 7200 is as follows:
Leak Resistance Between Lines
Leak Resistance Between Grounds
© SAMSUNG Electronics Co., Ltd.

Connecting C.O. Lines

Table 6.1 OfficeServ 7200 Line Conditions

Line Condition
OfficeServ 7200 Installation Manual
Leak Resistance
20 k or higher
20 k or higher