4) Connect the connector sides of the power cables to the socket in the external rectifier
of the OfficeServ 7200.
5) Power on the system.
6) Power on the external rectifier.
External batteries to be connected to an external rectifier
The external battery to be connected to an external rectifier has the same
capacity as the external battery used in the OfficeServ 7200. In addition, it is
handled in the same way and with the same cautions. For details about the
capacity of the external battery, refer to '4.1 Connecting external battery'.
Connecting a Rectifier
Do not connect the battery for power failure protection to a PoE connecting
terminal.
Use of External Rectifiers against Power Failure
Since an external rectifier for power failure operation is used along with PoE and
the system, the capacity of the external rectifier should be bigger than 20 A.
When the rectifier is used for power failure operation, restrictions occur in the
terminal connected to PoE. For more detailed information, refer to 'Cautions for
Connecting Stations'.