Fujitsu 1FINITY L100 User Manual page 411

Table of Contents

Advertisement

System Maintenance
Equipment Replacement
Step 22
Did the Main blade had a USB flash drive that was removed in
If YES:
Continue with next step.
If NO:
Proceed to
Step
26.
Step 23
Insert USB flash drive in the replacement Main blade.
Step 24
Turn the power on at the source and wait for the blade to initialize.
Warning: After the blade is powered up, power down within 15 minutes causes database corruption,
which leads to blade start-up failure and requires a return to factory for reprogramming.
Step 25
Verify that previous OSL and provisioning are restored to Main blade.
Step Result:
Procedure is complete.
Step 26
Is a database backup available for the blade being replaced?
If YES:
Proceed to
Restore Configuration Database
If NO:
Proceed to
Equipment Installation
Step 27
Turn the power on at the source and wait for the blade to initialize.
Step 28
Provision the tributary blade equipment.
Command:
> request set-shelfmode shelfid <x> shelfrole TRIB
Step Result:
Procedure is complete.
✓ 
This task is complete.
·
Release 19.1.1
Issue 1.1, May 2021
Step
and continue with next step.
and continue with next step.
1?
Fujitsu and Fujitsu Customer Use Only
411