HP 8340B Manual page 326

Synthesized sweepers
Hide thumbs Also See for 8340B:
Table of Contents

Advertisement

5-19.
EXTERNAL MODULE LEVELING ADJUSTMENT
Reference
Performance Test:
None
Service Section:
RF
Section
Description
In this
procedure,
the
DUT's
RF output
is
connected
to an
external detector and the detector's output
is
then connected to the DUT's XTAL LEVELING
input and
a
DVM. The DUT
is
then set to external
module leveling,
0
dBm and
10
dBm. At both levels, the DUT's Cal Constants are adjusted for the
correct DVM reading
and the correct
POWER dBm DISPLAY reading.
OUT
DIGITAL
VOLTMETER
^
EXT
INPUT
ADAPTER
APC-3.5(f)
to
APC-3.S(f)
(8340B
ONLY)
aaaoaooD
0
a
aaaaoaaoaa
0®0
a
cloaoaaaooa
ADAPTER
APC-3.5(f»
to
N(m)
(8341B
ONLY)
DETECTOR
BNC TEE
Figure 5-70.
External Module
Leveling
Adjustment Setup
Equipment
Digital
Voltmeter (DVM)
........
Detector, Positive
............
Adapters:
APC 3.5 (f)
to
APC 3.5 (f)
....
(required for HP 8340B
only)
APC 3.5 (f)
to
Type
N
(m)
....
(required for HP 8341B
only)
BNC (f)
to Dual Banana
......
BNC Tee
..................
..........
HP
3456A
HP 8473C
Option
003
.
.
,
HPP/N
5061-5311
HP
P/N 1250-1744
HP P/N 1251-2227
HP
P/N
1250-0781
HP 8340B/41B
Adjustments

Advertisement

Table of Contents
loading

This manual is also suitable for:

8341b

Table of Contents