[Appendix 1] Summary of MR-J4_B_-RJ020 + MR-J4-T20
(3) Change the parameter setting value.
After changing the setting value of the applicable parameter, click "OK" to write the setting value to the
motion controller and the servo amplifier.
Examples of changes of parameter setting values are shown below.
(a) Change of [Pr. 2 regenerative resistor] (hexadecimal parameter)
To change the setting value to "0020", enter "0020" as it is.
(b) Change of [Pr. 12 load inertia moment ratio relative to the servo motor (load inertia ratio) (decimal
parameter)
To change the setting value to "7.0", enter "0046" which is the value resulted from converting "70" to
the hexadecimal number.
(c) Change of [Pr. 39 Electronic dynamic brake operating time] (decimal parameter)
To change the setting value to "10000", enter "2710" which is the value resulted from converting
"10000" to the hexadecimal number.
(4) Since the parameter values changed in (3) are not reflected in the project, read the servo parameters in
communication and save them to the project.