26/40
Start-up
Please note:
Lifting movement speed
comes preset.
You can adjust the lifting
speed by throttling the
exhaust air:
1.
Set the operating pressure
of the maintenance unit to
4–6 bar.
2.
Mount the proper
workpiece pallet
(operating load).
3.
Move the cylinder, e.g.,
using the manual override
on the directional control
valve.
4.
Adjust the lifting speeds
at the throttle non-return
valves.
• Rotate in the "+" direction
The stroke becomes slower.
• Rotate in the "–" direction
The stroke becomes faster.
Bosch Rexroth AG, MIT: PE 2/X, PE 2/H, PE 4, 3 842 564 350/2020-06
8.2 Setting the lifting speed
Fig. 11:
Setting lifting speed (shown here on PE 2/H)
-
+
554 089-15