5.4

Mounting and Dismounting Covers

A gasket (i.e., rubber packing) is attached to each cover set surface of the dust- and
drip-proof type robot. Also, as the liquid gasket is coated to some areas, the mounting
and dismounting procedures of each cover differ from those of the standard robot.
Strictly observe the following procedures to mount and dismount each cover.
Before mounting and dismounting each cover, be sure to turn off the main
power ("POWER") switch.
When opening each cover, make sure that water or contaminant will not
enter the robot. If the power is supplied while water or contaminant is left in
the robot, you may get an electric shock or the robot may be damaged,
which is very dangerous.
5.4.1

Base Cover

In all, two (2) base covers are provided; the cover concurrently used for connector
panel and the cover concurrently used for battery box.
1)
The former cover is secured to the base with six (6) cross-recessed truss head
screws (M4 × 6; SUS) and two (2) hexagon socket head cap screws (M4 × 6;
SUS) by inserting the gasket. The gasket set surface is coated with the liquid
gasket. Remove the cover while carefully peeling off the liquid gasket, using a
slotted screwdriver, etc. As the cover is connected with the connectors inside,
DO NOT pull out the cover by force.
DUST- & DRIP-PROOF TYPE SPECIFICATIONS MANUAL
!
DANGER
– 42 –
STE 80765