DOK-SUPPL*-VPB*40.1***-PR02-EN-P
Rexroth IndraControl VPB 40.1 Control Cabinet PC
5.3
Installation Notes
Minimum distances for cooling, ca‐
bles, DVD drive and maintenance
Fig.5-5:
VPB 40.1 dimensions (top view)
●
Avoid installation locations exposed to direct sunlight/UV-light because
this causes additional heat development.
●
Install the control cabinet PC in a way ensuring easy access to the con‐
nector panel.
●
Provide a sufficient space of 50 mm (on all sides of the device) for sufficient
cooling and cable routing.
●
Lay all connecting cables in loops and use strain reliefs for all cables.
●
Keep as much distance as possible to noise sources.
For cooling, cables, maintenance and the DVD drive the following minimum
distances must be observed as shown in the following figures:
Provide sufficient distance for
25
hard disk replacement, if necessary
X20
X19
XCOM3
1
1
min. 50
F1
X10
XCOM1
Fig.5-6:
Minimum distances for cooling, cables, DVD drive and maintenance:
Front View
Bosch Rexroth AG
Dimensions, Installation
A3
A2
A1
XDP
XMouse
XUSB1
1
XUSB2
S1
XCOM2
XEthernet XKeyb.
XVGA
1
1
X39
X71
27/81
XLPT1
VI Vo T UPS HD