Voltage Supply - Bosch Rexroth lndraControl VPB 40.1 Project Planning Manual

Control cabinet pc
Table of Contents

Advertisement

20/81
Bosch Rexroth AG
Technical Data
4.3
24 V Voltage Supply
Max. inrush current
(cold start 25 °C)
Output voltages
+5 V
+12 V
-12 V
+20 V
ISO 6 V
Maximum output power
Efficiency
Fig.4-2:
Technical data of the power supply unit 115 V / 230 V
NOTICE
When maximum output currents are specified, please observe that the currents
are the maximum possible currents for the respective output voltage. However,
it is not possible to produce the maximum current from all output voltages, as
the maximum total output power of 160 W must not be exceeded.
Nominal input voltage
Input voltage range
Emitted interference and surge
immunity
Max. input current
Max. inrush current
Output voltages
+5 V
+12 V
+24 V
-12 V
ISO 6 V
Max. output power
Efficiency
Fig.4-3:
Technical data of the 24 V power supply unit
DOK-SUPPL*-VPB*40.1***-PR02-EN-P
Rexroth IndraControl VPB 40.1 Control Cabinet PC
40 A for nominal voltage AC 230 V
20 A for nominal voltage AC 115 V
Current (max.)
Tolerance (incl. residual ripple)
20 A
±5 %
3 A
±5 %
500 mA
±5 %
2 A
±5 %
200 mA
±5 %
160 W
0.8
The control cabinet PC VPB 40.1 can be dam‐
aged if the power supply unit is switched off if
the total output power exceeds 160 W.
DC 24 V
DC 24 V +20 %, -15 %
U
= 35 V (for t < 100 ms)
max
6 A for nominal voltage 24 V
25 A for nominal voltage 24 V
Current (max.)
Tolerance (incl. residual ripple)
13 A
±5 %
3 A
±5 %
2 A
±5 %
500 mA
±5 %
200 mA
±5 %
110 W
0.8

Advertisement

Table of Contents
loading

Table of Contents