Siemens SINAMICS S120 Device Manual page 42

Cabinet modules nema
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

System overview
2.11 Derating data
Table 2- 8
Derating factor of the output current as a function of the pulse frequency for devices with a rated pulse fre-
quency of 1.25 kHz
Order No.
Unit rating
6SL3720-...
[kW]
1TE36-1AU3
500 (315)
1TE37-5AU3
600 (400)
1TE38-4AU3
700 (450)
1TE41-0AU3
800 (560)
1TE41-2AU3
1000 (710)
1TE41-4AU3
1150 (800)
1TG28-5AU3
75 (75)
1TG31-0AU3
75 (90)
1TG31-2AU3
100 (110)
1TG31-5AU3
150 (132)
1TG31-8AU3
150 (160)
1TG32-2AU3
200 (200)
1TG32-6AU3
250 (250)
1TG33-3AU3
300 (315)
1TG34-1AU3
400 (400)
1TG34-7AU3
450 (450)
1TG35-8AU3
600 (560)
1TG37-4AU3
700 (710)
1TG38-1AU3
800 (800)
1TG38-8AU3
900 (900)
1TG41-0AU3
1000 (1000)
1TG41-3AU3
1250 (1200)
Note
Derating factors for pulse frequencies in the range between fixed values
For pulse frequencies in the range between the specified fixed values, the relevant derating
factors can be determined by linear interpolation.
42
Output current
at 1.25 kHz
[A]
2 kHz
Supply voltage 510 – 720 VDC
605
83 %
745
83 %
840
87 %
985
92 %
1260
92 %
1405
97 %
Supply voltage 675 – 1035 VDC
85
93 %
100
92 %
120
92 %
150
90 %
175
92 %
215
92 %
260
92 %
330
89 %
410
89 %
465
92 %
575
91 %
735
87 %
810
97 %
910
92 %
1025
91 %
1270
87 %
Derating factor at the pulse frequency
2.5 kHz
4 kHz
72 %
64 %
72 %
64 %
79 %
64 %
87 %
70 %
87 %
70 %
95 %
74 %
89 %
71 %
88 %
71 %
88 %
71 %
84 %
66 %
87 %
70 %
87 %
70 %
88 %
71 %
82 %
65 %
82 %
65 %
87 %
67 %
85 %
64 %
79 %
64 %
95 %
71 %
87 %
67 %
86 %
64 %
79 %
55 %
Manual, 04/2014, A5E03586450A
5 kHz
7,5 kHz
60 %
40 %
60 %
40 %
55 %
40 %
60 %
50 %
60 %
50 %
64 %
50 %
60 %
40 %
60 %
40 %
60 %
40 %
55 %
35 %
60 %
40 %
60 %
40 %
60 %
40 %
55 %
40 %
55 %
35 %
55 %
35 %
50 %
35 %
55 %
35 %
55 %
35 %
55 %
33 %
50 %
30 %
40 %
25 %
Cabinet Modules NEMA

Advertisement

Table of Contents
loading