Resetting Slk" Application; Handling "E00" Errors - Bosch Rexroth ID 40 Manual

Table of Contents

Advertisement

7.9.4

"Resetting SLK" application

This example allows the SLK to be reset in the DISCONNECTED link state. The actual
link state here is not important. In addition, all preconnect settings and auto mode
are deleted.
No.
Command-oriented data
exchange
1
Switch SLK to DISCON-
NECTED state
6
Turn off SLK in auto
mode
2
Stop pretransmit
4
Finish setting pretrans-
mit parameters
3
Delete pretransmit data
5
Finish setting param-
eters for unbuffered
prefetch
4
Delete unbuffered
prefetch
5
Finish setting param-
eters for buffered
prefetch
5
Delete buffered prefetch
6
Wait until actual link state is DISCONNECTED
7.9.5

Handling "E00" errors

This example terminates direct data exchange with the MDT. The commanded link
state DISCONNECT fails and the SLK switches to the ERROR state.
No.
Command-oriented data
exchange
1
Switch SLK to
DISCONNECTED state
2
Wait until actual link state is DISCONNECTED or ERROR
3
DISCONNECT unsuccessful, link state is now ERROR
4
Switch SLK to
DISCONNECTED state
5
Wait until actual link state is DISCONNECTED
6
The SLK is now in the initial DISCONNECTED state and the application can start over
CMD
Data0
Data1
Data2
0x06
0x00
0x03
0x00
0x06
0x00
0x03
0x00
0x08
0x05
0x08
0x01
0x08
0x04
0x0B
0x01
0x0B
0x04
0x0A
0x01
0x0A
0x04
CMD
Data0
Data1
Data2
0x06
0x00
0x03
0x00
0x06
0x00
0x03
0x00
3 842 530 344/2014-05, MIT: ID 40, Bosch Rexroth AG
PROOF COPy 1 | 20.05.2014 | FOR INTERNAL USE ONLy
Profibus DP
65/176
Data3
Data4
Data5
Data6
0x01
0x00
0x01
0x02
0x02
0x00
0x01
0x00
Data3
Data4
Data5
Data6
0x01
0x00
0x01
0x02
0x01
0x00
0x01
0x02