The Id 40/Slk Website; Navigating And Using The Id 40/Slk Website - Bosch Rexroth ID 40 Manual

Table of Contents

Advertisement

136/176 Web interface
Bosch Rexroth AG, MIT: ID 40, 3 842 530 344/2014-05
PROOF COPy 1 | 20.05.2014 | FOR INTERNAL USE ONLy

10.5 The ID 40/SLK website

The ID 40/SLK website provides all data and information on the ID 40 system. If an
MDT is located in front of the SLK at the time the website is accessed, all MDT data
can be displayed and even edited.
The layout of the pages is self-explanatory and the minimal text is in English for
international use.
The ID 40/SLK website can be accessed using your browser by entering the web
address
http://192.168.66.1/index.html
assigned to the IP address, see Chapter 10.4.1.3 "Assigning a name to the network
address".
10.5.1

Navigating and using the ID 40/SLK website

The ID 40/SLK website is divided into the "ID 40/SLK Homepage", which contains
links to the following pages:
• MDT register: contains the MDT status, MDT ID code and additional MDT
information as described in Chapter 4.2.3 "MDT register area"
• SLK register: contains the actual link state and other information described in
Chapter 5.3 "SLK register area"
• MDT data: allows MDT user data areas to be read and written, see Chapter 4.2.1
"MDT user data area"
• Fieldbus-specific settings and information, such as the Profibus node number
• System statistics and system information
• System logging and shell, supports system diagnostics as described in Chapter 12
"Diagnostics"
10.5.1.1 Switching the number format of displayed values
The default format of the SLK registers and fieldbus parameters is decimal, while
MDT data and MDT registers are displayed in hexadecimal form by default.
The data format for the SLK registers, MDT registers and MDT data can be switched
to decimal or hexadecimal. You can configure the MDT addresses "offset" and the
displayed MDT data independently on the MDT data page. Just use the "Number
Format" selection box.
Entering the values as described in the next section is completely independent of the
configured display format.
10.5.1.2 Syntax when entering values
Numerical values can be entered using the following number systems:
Number system
Hexadecimal
Decimal
Octal
Entering address ranges consists of a string of address ranges, each separated by a
comma or a space. An address range consists of a value for the start address, two
periods, then the end address.
or
http://id40/index.html
Format
0xnn
nnn
0nnn
if "id40" was
Value range
0x00 – 0xFF
0 - 255
0 - 0377

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents