The HF antenna can not only be pivoted upward or outward, it can also be rotated.
This makes various mounting situations possible.
The orientation of the HF antenna and the MDT must be the same, otherwise no
communication is possible with the MDT. The arrow stamped on the HF antenna
points toward the top of the MDT. The status LED is located on the upper edge of
the housing.
Carefully remove the HF antenna without damaging the connection cable.
Be sure to observe the orientation of the HF antenna as indicated by the arrow.

3.4 SLK electrical connection

3.4.1

Supply voltage

Insulation displacement is used to provide the 24 V supply voltage as per
EN 61131-2. This is also used for AS-i bus systems, so a black cable has to be used
for the connection as per AS-i specification.
Follow the ID 40/SLK assembly instructions.
Fig. 10: ID 40/SLK read/write head power connection
Never connect the yellow AS-i signal cable on the SLK, as this can result in the
ID 40 system and AS-i bus malfunctioning.
The functional grounding connection is optional and has to be connected for
conveyor sections that do not ensure electrical contact when mounting the SLK.
Functional grounding is typically unnecessary in Bosch Rexroth transfer systems, as
the mounting kits that come with the SLK provide enough grounding to the section
profiles.