The Details tab in ID 40 Status contains the Server IPv4 address, which refers to the
ID 40/SLK, and the Client IPv4 address, which refers to the computer.
If you computer already has network connections in the 192.168.66.x address range,
you have to use other IP addresses for connecting to the SLK to avoid conflicts.
You can configure other IP addresses both on the computer in the TCP/IP network
properties of the "ID 40" network connection and on the SLK using the ID 40/KONF
program.
Basic knowledge of network technology and familiarity with the network
environment of your computer are required to modify the network configuration.
Consult your network administrator before changing the settings.
The network connection to the SLK has to be terminated before the IP addresses
specified in the SLK can be changed.
Enter the command pppoption when prompted in the terminal window of the
ID 40/KONF program, followed by a space and the IP address of the SLK, then a
colon followed by the IP address of the computer.
Example:
ID 40/SLK > pppoption 10.66.82.8:10.66.32.12
Once the network connection is established, check the IP addresses as described
above: the SLK (server) is now at 10.66.82.8, and the computer (client) is now at
10.66.32.12.
Enter an IP address instead of Automatically find IP address in the TCP/IP network
properties of the "ID 40" network connection to replace the SLK default for the
computer (10.66.32.12 in the above example) with the one entered.
10.3.5.4 Multiple SLKs on one computer
Every SLK being connected requires a COM port on the computer. Add a new direct
network connection for every SLK as described above. A different network should be
configured for each SLK to avoid network address conflicts on your computer. See
also Chapter 10.3.5.3 "Changing the ID 40/SLK network address".
Table 49: Example of connecting four SLKs to one computer
SLK
SLK IP address
IP address of network connec-
no.
tion "directly" on computer
1
192.168.66.1
192.168.66.2
2
192.168.67.1
192.168.67.2
3
192.168.68.1
192.168.68.2
4
192.168.69.1
192.168.69.2
Web interface 131/176
Entry in ID 40/KONF:
ID 40/SLK > pppoption...
Default setting, no change
needed
...192.168.67.1:192.168.67.2
...192.168.68.1:192.168.68.2
...192.168.69.1:192.168.69.2
3 842 530 344/2014-05, MIT: ID 40, Bosch Rexroth AG