11.03
Table 3-18
Explanations of Fig. 3-14
Time
Explanation
t
Position controller clock cycle defined by the following MDs:
1
For 840D:
t
Monitoring clock cycle defined by the following MDs:
2
For 840D:
For 611 digital:
t
Time until standstill tolerance value is violated
3
t
Time until standstill tolerance value is detected (maximum 1 one monitoring clock cycle)
4
t
Response time required to initiate the configured stop response (maximum 2 monitoring clock cycles)
5
t
Time until the stop response sequence starts (time = 0, depends on configured stop response, refer to
6
Chapter 2, "Stop responses")
t
Time required to reach the shutdown speed with STOP B.
7
t
Time required to stop the axis with STOP B.
8
t
Time required to stop the axis with STOP A.
9
Note:
Each axis must be measured during start-up to determine the distance it travels between violation of the limit value
and coming to a standstill.
3.4.3

Overview of the machine data for the SBH function

Overview for 840D
Table 3-19
Overview of MD
Table 3-20
for 611 digital
© Siemens AG 2003 All Rights Reserved
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
MD 10050: $MN_SYSCLOCK_CYCLE_TIME
MD 10060: $MN_POSCTRL_SYSCLOCK_TIME_RATIO
MD 10090: $MN_SAFETY_SYSCLOCK_TIME_RATIO
MD1300: $MD_SAFETY_CYCLE_TIME
Overview of machine data for 840D
Number
Name
36901
$MA_SAFE_FUNCTION_ENABLE
36930
$MA_SAFE_STANDSTILL_TOL
36951
$MA_SAFE_VELO_SWITCH_DELAY
36956
$MA_SAFE_PULSE_DISABLE_DELAY
36960
$MA_SAFE_STANDSTILL_VELO_TOL
36970
$MA_SAFE_SVSS_DISABLE_INPUT
36971
$MA_SAFE_SS_DISABLE_INPUT
36980
$MA_SAFE_SVSS_STATUS_OUTPUT
36981
$MA_SAFE_SS_STATUS_OUTPUT (ab SW4.2)
Note:
Data is described in Chapter 4, "Machine data for SINUMERIK 840D"
Overview of machine data for 611 digital
Number
Name
1301
$MD_SAFE_FUNCTION_ENABLE
1330
$MD_SAFE_STANDSTILL_TOL
1351
$MD_SAFE_VELO_SWITCH_DELAY
1356
$MD_SAFE_PULSE_DISABLE_DELAY
1360
$MD_SAFE_STANDSTILL_VELO_TOL
Note:
Data is described in Chapter 4, "Machine data for SIMODRIVE 611digital"