2 General Information about Integrated Safety Systems
2.6 Basics of SINUMERIK Safety Integrated
Forced checking
The forced checking procedure is used to detect errors in the software and
procedure with Safety
hardware of the two monitoring channels. In order to do this, the safety-relevant
Integrated
parts in both channels must be processed in all safety-relevant branches at
least once during a defined period. Any errors in the monitoring channel will
cause deviations and will be detected by the crosswise data comparison.
The forced checking procedure of the shutdown path (test stop) must be
triggered by the user or integrated in the process as an automatic procedure,
e.g.:
The forced checking procedure also includes testing the safety-relevant
sensors and actuators. In this case, the entire circuit including the "safe
programmable logic" (SPL) is tested for correct functioning.
Error in the monitoring
Any errors in the monitoring channel result in deviations and are detected by
the crosswise data comparison.
channel
Dormant errors in the safety-relevant data of the two monitoring channels are
Crosswise data
comparison
discovered in the course of the crosswise data comparison.
In the case of "variable" data, there are tolerance values defined using machine
data by which amount the results of the two channels may deviate from one
another without initiating a response (e.g. tolerance for crosswise data
comparison of actual positions).
2-34
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
for stationary axes after the system has been powered-up
when the protective door is opened
in defined cycles (e.g. in 8-hour cycles)
in the automatic mode – dependent on the time and event.
Note
A defined 8-hour cycle is not mandatory in the automatic mode (when the
protective door is closed). A forced checking procedure after an 8-hour period
has elapsed can be combined with the next opening of the protective door.
Note
Errors that are discovered as a result of the forced checking procedure or
crosswise data comparison lead to a STOP F response (refer to Chapter 3,
"Stop responses") and initiate a further stop response when Safety Integrated
is active.
© Siemens AG 2003 All Rights Reserved